Superior Renovations Renovations Auckland 14 - Superior Renovations

How to Soundproof a Room When You Renovate in Auckland

Quick answer: To soundproof a room in a renovation, add mass and a sealed, insulated wall cavity, close the gaps at doors and glass, and treat the floor. Inside one house no Building Code level applies, so your specification sets it.

Most advice on how to soundproof a room is written for renters with foam panels and a door snake. If you’re renovating, you have a better option: the walls will be open, the linings are coming off anyway, and a quieter room costs far less to build in now than to bolt on later. The catch is that New Zealand’s Building Code says nothing about noise between two rooms in the same house, so nobody will set a standard for you.

Free cost calculator

How much will your renovation cost?

Answer a few questions and we’ll email you an Auckland price range.

Try our free cost calculators →

That leaves you, your designer and your builder to decide what quiet means for each room, and to write it into the plans before anyone orders plasterboard. This guide covers the rule that does exist, the wall, floor, door and window details that make the difference, the consent questions, and how to plan it so the bedroom next to the lounge actually gets the benefit.


Does the Building Code Say How Quiet a Room Has to Be?

Only between separate homes. Building Code clause G6, Airborne and impact sound, has one objective: to protect people from illness or loss of amenity caused by “undue noise being transmitted between abutting occupancies.” Its functional requirement applies to “building elements which are common between occupancies”, and its performance criteria set a Sound Transmission Class (STC) of no less than 55 for walls, floors and ceilings and an Impact Insulation Class (IIC) of no less than 55 for floors (Building Code, clause G6).

What STC and IIC actually measure

STC is a laboratory rating for airborne sound: voices, the television, music. The higher the number, the less gets through the wall or floor. IIC is the matching rating for impact sound through a floor: footsteps, a dropped toy, a chair dragged across boards. Both are measured in a test laboratory, and GIB’s noise control manual notes that once a system is built on site, field tests are allowed a 5-point relaxation, because real buildings rarely match the lab.

That gap between the lab and the house matters more than any single number. A wall rated in a test rig can lose much of its performance through a gap at the skirting, a power point cut straight through, or a floor that runs continuously under it.

Why your bedroom wall isn’t covered

A wall between your bedroom and your own lounge is not common between occupancies. It sits inside one household unit, so G6 does not reach it. Winstone Wallboards says as much in its own literature: its “Sub-Intertenancy” systems are described as “suitable for non-building code applications i.e. partitions within the same tenancy” (GIB Noise Control Systems manual).

So the standard inside your home is whatever your plans and specification say. If the drawings show a standard internal wall with one sheet of plasterboard each side and an empty cavity, that is what a builder is obliged to build, and it will meet the Code, because the Code asks nothing acoustic of it.

💡 Quick tip: Write the acoustic target into the specification room by room, for example “lounge to main bedroom wall: GIB system with a published STC of at least 46”, so the requirement survives into the quote and the build.

Where G6 does apply in a renovation

The picture changes the moment a renovation creates a second household. An attached granny flat, a dual-key layout or an apartment all put a wall or floor between two occupancies, and that element has to meet G6. Read how Sonder Architecture sets out fire and sound separation for a granny flat joined to the main house before you plan one, because the separating wall is a design and consent matter, not a finishing choice.

Apartment owners have a second layer on top: body corporate rules. Many restrict hard flooring or ask for an acoustic underlay, which is covered in our guide to body corporate flooring rules in an apartment renovation.

Important note: This is general information, not building advice. Schedule 1 of the Building Act exempts some work from consent, not from the Building Code. Before any wall is altered, have a Licensed Building Practitioner or engineer confirm what it does structurally, and check consent questions with Auckland Council.


How to Soundproof a Room Through the Walls

Walls are where most renovation budgets for quiet get spent, and where the published figures are clearest. GIB publishes laboratory STC ratings for single timber-frame internal walls built with 70 x 45 mm minimum studs at 600 mm centres, Pink Batts R2.2 (90 mm) glass wool between the studs and nogs, and a bead of GIB Soundseal acoustic sealant around the perimeter. Only the linings change from one system to the next.

Laboratory STC ratings: single timber-frame internal walls

Same frame and 90 mm glass wool infill; linings change. The last bar is the Building Code minimum between separate homes, for comparison.

1 x 10 mm GIB Standard Plasterboard each side (GST102)

STC 39

2 x 10 mm GIB Standard Plasterboard each side (GST104)

STC 44

2 x 10 mm GIB Braceline/Noiseline each side (GNT104)

STC 46

2 x 13 mm GIB Braceline/Noiseline each side (GNT134)

STC 48

Building Code G6 minimum, between separate occupancies

STC 55

Source: GIB Noise Control Systems manual, single timber frame sub-intertenancy systems; Building Code clause G6.

Mass: more and heavier linings

Read the card from top to bottom and the pattern is plain. Doubling the standard 10 mm sheet on each side moves the rating from 39 to 44, and two layers of 13 mm Noiseline each side reach 48. Each extra layer adds weight the sound has to move, and it costs you a little floor space on each face of the wall. Even the best single-frame wall in that table sits 7 points under the Code minimum between two homes, which tells you why separate dwellings use double frames instead.

The cavity: fill it, but don’t crush it

Every rating above assumes the cavity is filled with glass wool. GIB’s manual warns installers not to compress the infill, because packed insulation can bridge the two linings and carry sound straight across. Its advice is to slice the batts neatly around pipes and cables instead of stuffing them in. If your renovation is rewiring the room anyway, that detail is easy to get right while the wall is open, and close to impossible to check once it is lined.

Renovations rarely open both faces of a wall at once: the main bedroom gets redone while the lounge beside it stays. GIB lists systems for exactly that case, with two layers on one side and a single layer on the other. With 10 mm Noiseline, one layer one side and two the other is rated STC 44; with 13 mm sheets the same arrangement reaches STC 46. Both beat the plain single-sheet wall at STC 39, and both leave the far room untouched.

The catch is the cavity. Those ratings still assume glass wool between the studs and sealant at the edges, so a one-sided job only works if the wall is opened from your side and the cavity filled properly before the extra sheet goes on. Screwing a second layer over an empty cavity is a different, unrated wall.

Decoupling and the details that leak

The manual is blunt about single-stud walls: minor deviations from the specification can cost a significant amount of performance.

Three details catch most renovations. First, stud spacing: the ratings are based on 600 mm centres, and GIB says that closer centres will significantly lower the STC. Second, power points: never mount them back-to-back, because a pair of holes in the same bay is a short cut for sound. Third, flanking, the sound that goes around the wall through a continuous floor, ceiling cavity or junction rather than through it.

For a wall that needs to do more, the manual lists systems that separate the two linings: resilient rails fixed to one side, staggered studs and double frames. These cost more floor area and more labour, and the rail systems need careful installation, because one screw driven through the rail into a stud can bridge the gap the rail exists to create.

💡 Quick tip: Ask your builder to show you the acoustic sealant bead and the uncut batts before the second sheet of lining goes on. It takes five minutes on site and it is the only chance anyone gets to check it.

Do you need consent to soundproof an internal wall?

Usually not, with important exceptions. Schedule 1, clause 11 of the Building Act exempts building work on an internal wall or doorway in an existing building unless the wall is load-bearing, a bracing element, a firewall, part of a specified system, or masonry such as brick or concrete block. Clause 12 exempts work on the internal linings and finishes of any wall, ceiling or floor of an existing dwelling (Building Act 2004, Schedule 1).

The exceptions are the walls you can’t identify by knocking on them. Some internal walls in a timber-framed house carry roof or floor loads or brace the building, and changing their linings or framing is a different conversation. Section 17 of the Act also applies whether or not consent is needed: all building work must still comply with the Building Code. We plan this kind of work into a whole-home renovation that is designed in-house before any wall comes down, so the structure question is answered on paper first.

Want a price for your renovation?
See the calculators →

Floors and Ceilings: Stopping Footsteps as Well as Voices

If the noise you want gone comes from upstairs, a wall upgrade won’t touch it. Floors carry two kinds of sound. Airborne sound is the same as through a wall: voices and television coming down through the ceiling. Impact sound starts in the floor itself, when someone walks, runs or drops something, and the structure carries it into the room below.

Why the floor covering matters so much

GIB’s floor and ceiling figures show how much impact noise depends on what you walk on. One of its timber-joist floor and ceiling systems with two layers of 13 mm standard plasterboard on the ceiling below carries an STC of 53, but its impact rating is published as a range, IIC 42 to 65, depending on the floor covering. Same joists, same ceiling, and the impact result swings by more than 20 points on the choice between a hard floor and a soft one.

That makes the floor covering upstairs one of the biggest acoustic choices in a two-storey house. If you want timber, vinyl plank or tiles in an upstairs bedroom or hallway, ask for the acoustic underlay to be specified with the flooring, not added later.

Carpeted bedroom with a desk and lamp beside sliding glass doors that open onto a timber deck
Carpet over underlay softens footfall noise for the room below; hard floors upstairs need their underlay specified.

What you can do from the ceiling below

When the floor above is staying, the work moves to the ceiling underneath. The same principles from the wall section apply: more lining mass, a filled cavity and as few holes as possible. Recessed downlights are the awkward part, because every one is a hole through the layer doing the work, so plan the lighting with the acoustic goal in mind instead of cutting a dozen openings into a new ceiling.

Clause 12 of Schedule 1 covers work on the internal linings of a ceiling in an existing dwelling, so relining a ceiling is generally consent-exempt. Clause 13 separately exempts installing thermal insulation in an existing building, except in an external wall or a firewall. The structure is a different matter: if a floor needs new joists or a change to how it is supported, that is building work for a designer and an LBP to scope.

💡 Quick tip: Before you choose a hard floor for an upstairs room, stand in the room below while someone walks across the existing floor in shoes. That is the noise you are designing out.

Open-plan spaces and the noise inside one room

Some noise complaints have nothing to do with walls. A large open-plan kitchen, dining and living space with hard floors, glass and a high ceiling is loud because sound bounces around inside it. Soft furnishings, rugs and curtains help, and so does keeping one quieter room you can close a door on. Our guide to the trade-offs of opening up an Auckland living area covers how to keep the open feel without the echo.


Doors, Windows and Noise From Outside

A wall rated STC 48 with a hollow door in it performs like the door. Sound takes the easiest path, and in most rooms the easiest path is the door, the gap under it, and the glass in the outside wall. GIB’s manual lists doors and glazing among the details that decide how a noise control wall performs once it is built.

Internal doors and the gap underneath

A solid-core door carries far more mass than a hollow-core one, and mass is what the wall ratings above reward, and perimeter seals plus a drop seal at the bottom close the gaps around it. There is a trade-off to check: some rooms rely on the gap under the door for air movement, especially where a heat pump or ventilation system draws air through the house. Seal a bedroom tight without sorting the air supply and you swap noise for a stuffy room.

Sliding and cavity doors are harder to seal tightly than a hinged door, so if a media room or home office is on your list, choose a hinged door for that room even if the rest of the house uses sliders.

Glazing and the outside wall

For traffic, the neighbour’s heat pump or a dog two sections over, the glass and the gaps around opening sashes are often where the noise gets in. Imagine a bedroom on a busy road in Mt Eden with single-glazed sashes and a gap at every window: no amount of internal wall work fixes that room, because the noise isn’t coming through the internal walls at all.

Upgrading the glass is the first move. Our guide to how retrofit double glazing works in Auckland homes explains when new glass in existing frames makes sense and when new joinery does.

Want a price for your double glazing?
Open the calculator →

External walls are a consent question

Here is the rule that surprises people. Schedule 1 clause 13 exempts installing thermal insulation in an existing building, but not in an external wall, so adding insulation to an outside wall to cut road noise needs consent unless another exemption applies. That makes the external wall a job to plan into a wider renovation or reclad, where the wall is open and consented anyway, rather than a weekend upgrade.

💡 Quick tip: Record where the noise actually comes from before you spend anything. Stand in the room at the noisy time of day with the door shut, then with the window shut, and note which change makes the difference.


Planning a Quieter Room Into Your Renovation

We’ll be upfront: soundproofing is far easier to build in while the linings are off than to add once the room is painted, and most of that difference is sequencing. The best results come from deciding which rooms need it at the design stage, so the wall systems, door types, power point positions and flooring are all drawn and priced together.

Which rooms to prioritise

Not every wall needs an upgrade. Look for the pairs where a loud room sits against a quiet one: a main bedroom beside the lounge or media room, a child’s room next to the kitchen, a home office off the family room, and any bedroom that shares a wall with the laundry or a bathroom. Those are the walls worth the extra linings and sealant.

Children's bedroom with a cot, a single bed and a painted chest of drawers beside sliding doors to a deck
A child’s bedroom is often the room that most needs a quieter wall to the living areas.

What to put on the list for your designer

  • The room pairs that need separation, and the noise you’re trying to stop in each one.
  • A named wall system with a published STC rating for each of those walls.
  • Power points and switches offset, never back-to-back, on any acoustic wall.
  • Door type and seals for each quiet room, with ventilation checked.
  • Flooring and underlay for any upstairs room, chosen with the ceiling below in mind.
  • Where noisy appliances such as washing machines, dryers and televisions sit, kept off the walls you are trying to quieten.

GIB’s manual makes the appliance point directly: washing machines, wall-mounted dryers, speakers and televisions pass vibration into the structure, so keep them off walls that separate living areas from quiet rooms such as a study or bedroom.

Timing is most of the job. The acoustic layer goes in after the pre-line work, once the electrician and plumber have run their cables and pipes through the open frame, and before the linings go up. That short window is when the batts are cut around the services, the power points on acoustic walls are checked for offset, and the sealant bead goes down. Miss it and the next chance is to strip the wall again.

It also helps to agree who checks it. On a renovation with a dedicated project manager, the acoustic walls can sit on the same pre-line checklist as the plumbing and wiring, so the details are signed off before a sheet of plasterboard covers them. If your renovation is staged, put the acoustic walls in the stage where those rooms are already open rather than reopening a finished room later.

Converted spaces: garages, studios and gyms

Garage conversions are a common place for a loud room. A music room, a home gym or a teenager’s retreat in the old garage needs its walls, ceiling and door treated from the start, especially where the garage is attached to the house. See how we handle turning a garage into a music room, gym or home office.

💡 Quick tip: If you hear the noise mainly at night, test at night. A quiet weekday afternoon walkthrough will tell you nothing about the neighbour’s car or the late television in the next room.

What it costs

There is no honest single number for soundproofing a room, and we don’t publish one.

The price depends on how many walls, which system, whether the ceiling and floor are part of it, and whether the work rides on a renovation that already has the linings off. The fair way to price it is as a line in the renovation quote, against the specific walls and systems on your plans.

Superior Renovations has completed more than 1,000 Auckland renovations since 2017, and every project we take on is designed in-house before work starts, so these choices are made and priced before the build. Call us on 0800 199 888 or book a visit, and you’ll know the price, the timeline and exactly what’s included before any work starts.


The Quiet Room Starts on the Drawings

A quieter bedroom or office isn’t a product you buy at the end of a renovation. It is a set of decisions about walls, floors, doors and glass, and inside your own home nobody makes them for you. Get them onto the drawings, name the systems, and check the details on site while the walls are still open.

➡ Book your free in-home consultation with Superior Renovations
➡ put a price range around the rest of your renovation with our free calculators
➡ Request a free feasibility report for your project


How do you soundproof a room in an existing house?

Add mass to the walls with extra or heavier plasterboard layers, fill the cavity with glass wool without compressing it, seal the perimeter with acoustic sealant, and deal with the door and any glazing. GIB publishes laboratory ratings for single timber-frame internal walls from STC 39 with one 10 mm standard sheet each side to STC 48 with two 13 mm Noiseline sheets each side. Doing it during a renovation, while the walls are open, is far simpler than retrofitting.

Does the NZ Building Code require soundproofing between rooms?

Not inside one home. Building Code clause G6 applies to building elements common between occupancies, such as the wall between two flats or a granny flat and the main house. There it sets an STC of no less than 55 for walls, floors and ceilings and an IIC of no less than 55 for floors. Between two rooms in the same household, your plans and specification set the standard.

Do I need building consent to soundproof an internal wall?

Usually not. Schedule 1 clause 11 of the Building Act exempts work on an internal wall in an existing building unless the wall is load-bearing, a bracing element, a firewall, part of a specified system or masonry. Clause 12 exempts internal linings. The work must still comply with the Building Code. Have an LBP confirm what the wall does structurally, and check with Auckland Council if you are unsure.

What STC rating should a bedroom wall have?

No rule sets one inside a house, so it is your choice. For comparison, the Building Code asks for STC 55 between separate homes, and GIB lists single timber-frame internal walls rated from STC 39 to STC 48 depending on the linings. Name the system and its published rating in your specification for each wall you want quieter, so it is priced and built that way.

How can I block noise from a shared wall?

If the wall is shared with another household, such as a flat, townhouse or granny flat, it is a separating element under Building Code clause G6 and the fix is a design job, often a separate frame, not a lining swap. In an apartment, check the body corporate rules before changing anything. Inside your own home, heavier linings, a filled cavity, sealed edges and offset power points make the biggest difference.

Can you completely soundproof a room?

Not in an ordinary house renovation. Even the best single-frame wall in GIB tables sits under the STC 55 the Code asks for between separate homes, and sound also travels through doors, glass, floors and junctions. The realistic goal is a noticeably quieter room, built into the walls, door and floor together rather than added to one of them.

Is acoustic insulation the same as thermal insulation?

Glass wool batts do both jobs, and the GIB wall ratings assume Pink Batts R2.2 (90 mm) in the cavity. For consent, Schedule 1 clause 13 exempts installing thermal insulation in an existing building except in an external wall or a firewall, and internal wall work falls under clause 11. Insulating an external wall to cut road noise therefore needs consent unless another exemption applies.

How do I stop footsteps from upstairs?

Impact noise is controlled mostly by what is on the floor above and how the ceiling below is built. GIB publishes one timber-joist floor and ceiling system at IIC 42 to 65 depending on the floor covering, so a soft covering on a good underlay makes a large difference. Where you want hard flooring upstairs, specify an acoustic underlay with it and plan the ceiling below with few penetrations.

How much does it cost to soundproof a room in Auckland?

We do not publish a single figure, because the price depends on how many walls, which system, whether the ceiling and floor are included and whether the linings are already coming off. The fair way to price it is as a line in your renovation quote against the walls on your plans. Book a free in-home consultation and we will price it with the rest of the work.

Related guides


Further Resources

  1. Featured projects and Client stories to see specifications on some of the projects.
  2. Real client stories from Auckland

Need more information?

Take advantage of our FREE Complete Home Renovation Guide (48 pages), whether you’re already renovating or in the process of deciding to renovate, it’s not an easy process, this guide will help you avoid costly mistakes.

Download Free Renovation Guide (PDF)


Q Mastercard: up to 18 months interest-free, available through Superior Renovations

Have you been putting off getting renovations done?

We have partnered with Q Mastercard ® to offer up to 18 months interest-free, so you can enjoy your new home now and stress less.

Learn More about Interest-Free Payment Options*

*Lending criteria, fees, terms and conditions apply. Mastercard is a registered trademark and the circles design is a trademark of Mastercard International Incorporated.

 

 


Still have questions unanswered?

Book a no-obligation consultation with the team at Superior Renovations, we’d love to meet you to discuss your renovation ideas!

    Services

    Home RenovationKitchen RenovationBathroom RenovationOutdoor RenovationHouse ExtensionCommercialDesign ServicesOther

    By submitting this form, you agree to receive communications from us via email or text regarding our services, you can unsubscribe at any time.

    This site is protected by reCAPTCHA and the Google

    Privacy Policy and Terms of Service apply.


    References

    1. Building Regulations 1992, Schedule 1 (Building Code), clause G6 Airborne and impact sound
    2. Building Act 2004, section 17 and Schedule 1 clauses 11, 12 and 13
    3. Winstone Wallboards, GIB Noise Control Systems manual